Datastick® InSpect makes it easy to set up an inspection route on a PC, download it to the handheld computer, and upload the collected data to the PC.
To begin, start the InSpect RouteMaker application on your PC and build a hierarchical route. You can copy and paste entire machine setups to make the route-building even faster. In addition to vibration data, InSpect RouteMaker software enables you to build checklists and set up simple yes/no questions. (For example: simple questions that are sometimes overlooked, such as, “Is the machine running?” Yes/No.) If you wish, you can also include instructions to the operator on what to do if technician on the route spots trouble. When you've finished creating the route, click the mouse and the route loads onto the handheld computer.

As the technician runs the route, he simply taps NEXT on the handheld computer's touchscreen and takes the read. (A built-in safeguard prevents attempts to get a read from a sensor that hasn't settled.) If he needs to deviate from the route sequence, he can choose the next available inspection station from a list.

When the technician is finished running the route, he hands you the device and you upload the data to your PC and import it into a special version of Datastick Reporting System software for InSpect, where you can trend the data and create reports.

If you see that a machine needs full vibration analysis, you can open its vibration data in Datastick Reporting System for VSA or DAART (Datastick Advanced Analysis and Reporting Toolkit) software.
- Hierarchical route creation on the PC
- Routes download to the handheld computer used in the Datastick VSA-Series vibration spectrum analyzer
- 100 machines per route, unlimited number of routes
- Vibration inspection points configurable for acceleration, velocity, or displacement; maximum frequency, low-frequency cutoff, amplitude range, sensor sensitivity, alarm limits
- Optional checklist inspection points
- Optional numerical-input inspection points for recording gauge readings
- Optional yes/no inspection points
- Ability to save vibration waveform for later analysis in Datastick Reporting System for VSA or DAART (Datastick Advanced Analysis and Reporting Toolkit) software
- Optional supervisor-specified remedy steps for failed tests
- Handheld software leads the data-gathering technician through the route step-by-step
- Handheld software prevents the user from getting reads until the sensor has settled
- Data uploads to PC and imports into a special version of Datastick Reporting System software for InSpect for trending and reporting
PC system requirements:Microsoft® Windows XP or Windows Vista, and Microsoft Office® 2003 or 2007 or Microsoft Excel® 2003 or 2007
|